Product: Agilent Connected Instrument Device (CID) for OpenLab CDS Audience: Agilent Support, IT/network administrators Support reference: Boot / activation connectivity

caution

The diagnostic procedures on this page are intended for IT administrators familiar with Linux commands. Incorrect use of the underlying tools can misconfigure the CID and render it inoperable. Proceed only if you are comfortable working in a Linux environment.


Symptom​

You hear a sequence of one, two, three, or four beeps from the CID during or after startup. The sequence may repeat.


Root cause​

Each beep count corresponds to a different check during boot or activation. During activation, failed checks repeat about every 30 seconds:

  • 1 beep, Corporate NIC unavailable. The Corporate NIC is not connected or has no IP address. Possible causes include a disconnected cable, a disabled switch port, or swapped Corporate and Instrument NIC cables.
  • 2 beeps, registration API unreachable. The Corporate NIC has link and an IP address, but the CID cannot reach the Registration API on TCP 443. Possible causes include firewall, DNS, or routing problems. Swapped Corporate and Instrument NIC cables can also produce this pattern when the instrument network has its own DHCP server.
  • 3 beeps, no matching CID record in CID Hub. The CID reached the registration API and CID Hub recognized its MAC, but no CID record is linked to that MAC. Either the CID has not been added to the organization in CID Hub, or it was added under a different MAC.
  • 4 beeps, activated CID cannot reach registration API on boot. A previously activated CID booted without connectivity to the Registration API. A registered CID with OpenLab CDS already installed emits the 4-beep pattern once and continues booting; an unregistered or partially activated CID repeats the pattern every 30 seconds until connectivity is restored.

Confirm this is the right document​

Count the beeps in the pattern, then use the following table to identify the failing check.

You observeNext step
1 beepThe Corporate NIC is disconnected or has no IP address. Continue with Step 1.
2 beepsThe CID has network link but cannot reach the registration API. Continue with Step 2.
3 beepsThe CID reached the registration API but no matching CID record was found in CID Hub. Continue with Step 3.
4 beepsA previously activated CID cannot reach the registration API on this boot. Continue with Step 4.
No beeps, but CID is offline in CID HubThis page does not apply. See Verify CID internet connectivity instead.

Affected services​

The effect depends on the beep pattern. Two or three beeps prevent activation from completing. One beep means the Corporate NIC is unavailable. Four beeps mean the CID cannot communicate with CID Hub; a registered CID continues booting, but CID Hub management remains unavailable until connectivity is restored.

For the complete list of domains the CID requires for activation and registration, see the Internet requirements section of System requirements.


Prerequisites​

  • Physical access to the CID and to the Corporate NIC cable.
  • For 2- and 4-beep diagnosis: command-line access to the CID via SSH or direct console connection, with nc, curl, and nslookup available.
  • For 3-beep diagnosis: CID Hub access for the customer organization, with permission to view and add CIDs.
  • The 12-character Corporate NIC MAC address printed on the QR-code sticker affixed to the CID chassis.

Diagnostic steps​

Step 1. Resolve a 1-beep pattern (Corporate NIC unavailable)​

Check the Corporate NIC connection and IP address:

ip address show
ResultNext step
Corporate NIC interface shows state DOWN or NO-CARRIERThe cable is unplugged, faulty, or the switch port is disabled. Reseat the cable and verify the switch port is active.
Corporate NIC interface shows state UP but no IP addressCheck the network's address assignment and confirm the cables are in the correct ports.
Corporate NIC interface shows state UP with an IP addressConfirm the cables are in the correct ports. If they are swapped, restore the correct cable assignment, then reboot.
Pattern persists after these checksReboot the CID. If the 1-beep pattern continues, open a support ticket with Agilent Support and note the beep count and the steps already attempted.

Step 2. Resolve a 2-beep pattern (registration API unreachable)​

Verify reachability of the registration API:

nslookup hub-ac-registration-api.prd-51.aws.agilent.com
nc -zv hub-ac-registration-api.prd-51.aws.agilent.com 443
ResultNext step
nslookup failsDNS is misconfigured. See DNS resolution failure.
nc returns Connection refused or times outTCP 443 to the Registration API is blocked. See TCP port 443 blocked.
Both succeed, but the CID continues to beep twiceThe network layer is reachable; the registration call itself is being blocked or rejected. Work through TLS handshake failure, Certificate validation errors, and NTP time synchronization failure in that order.
Cables look correct from the front but the CID still beeps twiceConfirm the Corporate NIC cable is in the Corporate NIC port and the Instrument cable is in the Instrument NIC port. A cable swap can produce two beeps when the instrument network has its own DHCP server.

For a broader first-pass triage across all network failure modes, run Verify CID internet connectivity before working through the linked pages individually.


Step 3. Resolve a 3-beep pattern (no matching CID record)​

The CID has reached CID Hub, but no CID record is linked to its device record:

  1. Read the MAC address and PIN from the QR-code sticker on the CID chassis.
  2. In CID Hub, open Settings > Devices and find the device by its MAC or Code.
  3. Check its Status and CID columns.
ResultNext step
The device is New and has no linked CIDAdd a CID using the PIN. See Activate a CID.
The device is missing, its MAC differs from the label, or it already has a linked CIDContact Agilent Support with the PIN and MAC from the label.

Step 4. Resolve a 4-beep pattern (activated CID cannot reach API)​

This pattern indicates a previously activated CID has lost connectivity to the Registration API. If OpenLab CDS is already installed on the CID, the 4-beep pattern is emitted once and the CID continues booting; in-progress CDS acquisitions continue to function, but no Hub-driven management is possible until connectivity is restored. If the CID is partially activated (OpenLab CDS not yet installed), the 4-beep pattern repeats every 30 seconds.

Run the same reachability checks as Step 2:

nslookup hub-ac-registration-api.prd-51.aws.agilent.com
nc -zv hub-ac-registration-api.prd-51.aws.agilent.com 443
ResultNext step
nslookup failsDNS resolution for the Registration API has broken since activation. See DNS resolution failure.
nc returns Connection refused or times outAn outage or firewall change has blocked the CID's outbound path to the Registration API. See TCP port 443 blocked.
Both succeed, but the 4-beep pattern recurs across rebootThe network layer is reachable; the registration call itself is being blocked or rejected. Work through TLS handshake failure, Certificate validation errors, and NTP time synchronization failure in that order. If the pattern still persists, open a support ticket with Agilent Support and note that the 4-beep pattern recurs despite the Registration API being reachable.

Resolution​

Apply the action for the diagnostic step that identified the cause.

Recommended actionApplicable when
Reseat or replace the Corporate NIC cable; verify the switch port is activeStep 1 confirmed no link
Restore the correct Corporate / Instrument cable assignmentStep 1 or Step 2 identified swapped cables
Apply the resolution from DNS resolution failureStep 2 or Step 4 showed DNS failure
Apply the resolution from TCP port 443 blockedStep 2 or Step 4 showed TCP 443 blocked
Work through TLS handshake failure, Certificate validation errors, and NTP time synchronization failureStep 2 or Step 4 succeeded on TCP but the beep pattern persisted
Add a CID in CID HubStep 3 shows a New device
Contact Agilent SupportStep 3 shows a missing or inconsistent device record, or Step 1 or 4 did not resolve the problem

Last updated: